Fallen bacteria test with MC-Media Pad


Various inspection methods


Pdf version can be downloaded here.


Fallen bacteria inspection method using MC-Media Pad
   

Purpose of inspection


 HACCP requires process control, and the fallen bacteria test is effective in controlling the manufacturing process.


Inspection method


1) Leave the cover film open for a specified time at the inspection site as below. Fallen bacteria will be captured on the MC-Media Pad.




2) Add 1 ml of sterilized saline onto this MC-Media Pad, close the cover film.




3) Put this MC-Media Pad into incubator, incubate at the temperature and time specified for each product.




4) Count the number of colonies according to interpretation of each product.



Notice)
 MC-Media Pad is designed to perform at the addition of 1 mL sample solution. If fallen bacteria are captured onto MC-Media Pad after addition of sterilized saline, evaporation of liquid can make accurate counting of colonies difficult. Be sure to add 1 mL sterilized saline after capturing of fallen bacteria.